VOR/ILS Analyzer EVS200
0796.1800.02 E-8 42
Chapter 3: Operation
Command FA0
command function
FA0 <fast DDM measuring off> deactivating the fast DDM measurement
The command FA0 switches off the fast DDM measurement.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
input:
FA0 <CR>
fa0 <CR>
READY <CR/LF>
READY <CR/LF>
Command D1
command function
D1 <display information> switch over to display1
The command D1 enables the switching over to the content of display1 in the VOR / ILS mode.
This is prediction for reading out the data of the corresponding mode (VOR/ILS).
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
input:
D1 <CR>
d1 <CR>
READY <CR/LF>
READY <CR/LF>
Command D2
command function
D2 <display information> switch over to display2
The command D2 enables the switching over to the content of display2 in the VOR / ILS mode.
This is prediction for reading out the data of the corresponding mode (VOR/ILS).
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
input:
D2 <CR>
d2 <CR>
READY <CR/LF>
READY <CR/LF>