Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or duct. You
must provide two permanent openings: one within 12 inches
of the ceiling and one within 12 inches of the oor. Connect
these items directly to the outdoors or spaces open to the
outdoors. These spaces include attics and crawl spaces.
Follow the National Fuel Gas Code NFPA 54/ANS Z223.1.
Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
Ventilation Air From Inside Building
This fresh air would come from adjoining unconned space.
When ventilating to an adjoining unconned space, you must
provide two permanent openings: one within 12 inches of the
wall connecting the two spaces (see options 1 and 2, Fig. 2).
You can also remove door into adjoining room (see option
3, Fig. 2). Follow the National Fuel Gas Code NFPA 54/ANS
Z223.1. Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet
air into attic if attic has a thermostat-controlled power vent.
Heated air entering the attic will activate the power vent.
Rework worksheet, adding the space of the adjoining
unconned space. The combined spaces must have enough
fresh air to supply all appliances in both spaces.
Fig. 2 - Ventilation Air from Inside Building
Fig. 3 - Ventilation Air from Outdoors