CAUTION FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use any phone in your building.
· Immediately call your gas supplier from a neighbors phone. Follow the gas
suppliers instructions.
· If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
INSTALLER: DO NO DISCARD THIS MANUAL LEAVE FOR HOMEOWNERS FUTURE
REF
ERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY, OR LOSS OF LIFE.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to
Air For Combustion and Ventilation
section on page
7
This appliance may be installed in an aftermarket*, permanently located
manufactured (mobile) home, where not prohibited by local codes. This appliance
is only for use with the type of gas indicated on the rating plate. this appliance is
not convertible for use with other gases.
WARNING: This appliance is
equipped for (Natural and Propane)
gas. Field conversion is not permitted
other than between natural or
propane gases.
VENT-FREE FIREPLACE
MODEL: EDP200T-O
EDP200T-C
www.PartsFor.com 1-800-446-1446
For replacement parts contact:
1-866-607-2787
Przeglądanie stron 0
1 2 3 4 5 6 ... 24 25

Podsumowanie treści

Strona 1 - VENT-FREE FIREPLACE

PC-ED200T651-0805 CAUTION – FOR YOUR SAFETY – Do not store or use g

Strona 2 - TABLE OF CONTENTS

Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point of fireplace to any combustible side wall should not be less t

Strona 3

INSTALLATION CONTINUED The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce inc

Strona 4

INSTALLATION CONTINUED CAUTION: Two gas line installations at the same time is forbidden. Do not open cover while the heater is running. Heater is p

Strona 5

CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks immediately. Pressu

Strona 6

INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts may result in property damage o

Strona 7

OPERATING HEATER WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, perso

Strona 8

THERMOSTATIC CONTROL OPERATION The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the bu

Strona 9

(Match Light) 1. Remove screen by lifting and pulling forward. 2. Follow steps 1 through 7 under MANUAL OPERATING Lighting Instructions. 3. With C

Strona 10 - 1-866-607-2787

CLEANING AND MAINTENANCE WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shook or perso

Strona 11

TROUBLESHOOTING NOTE: Turn the control knob to “OFF” position first and wait for one minute. Then turn the control knob to the “ON” position. Plea

Strona 12

TABLE OF CONTENTS Important Safety Information...

Strona 13

OBSERVED PROBLEM REMEDY POSSIBLE CAUSE ODS/pilot lights but flame goes out when control knob is released. 1. Control knob is not fully pressed in. 2

Strona 14

OBSERVED PROBLEM REMEDY POSSIBLE CAUSE White powder residue forming within burner box or on adjacent walls or furniture 1. When heated, the vapors f

Strona 15

REPLACEMENT PARTS NOTE: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER

Strona 16

PARTS LIST EDP200T-O & EDP200T-C This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed

Strona 17

PARTS LIST EDP200T-O & EDP200T-C This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed u

Strona 18

Printed in China 25 www.PartsFor.com 1-800-446-1446For replacement parts contact: 1-8

Strona 19

IMPORTANT SAFETY INFORMATION IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater.

Strona 20

1. Do not place Propane/LP supply tank(s) inside any structure. Place Propane/LP supply tank(s) outdoors. 2. This heater shall not be installed in a b

Strona 21

PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feat

Strona 22

UNPACKING 1. Remove top inner pack. 2. Tilt carton so that heater is upright. 3. Remove protective side packaging. 4. Slide heater out of carton. 5.

Strona 23

AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provision

Strona 24

2. Divide the space volume by 50 cubic feet to determine the maximum BTU/hr the space can support. (volume of space) ÷ 50 cu. ft. = (Maximum

Strona 25

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12&qu